CED Hammond Manufacturing P T1182 30 Transformer Hammond Manufacturing Toroidal Power 30V / 60V secondary P13626182CED-P-T1182K30 https://cdnimages.opentip.com/full/CED/CED-P-T1182-30.jpg Hammond Manufacturing P T1182 30 Transformer Hammond Manufacturing Toroidal Power 30V / 60V secondary Manufacturer Part Number: P-T1182-30Dual 117/234 VAC primary, ~\\frac{50}{60}~ Hz. operation. 60 V series, 30 V parallel secondary.Toroidal transformers arelow profilelightweightcool running / high efficiencyhave low stray magnetic flux leakage (low EMI) due to core shapeFeatures:Supplied with two neoprene rubber insulating pads, one metal centering washer and all mounting hardwareMinimum 8\" long flexible leadsManufactured using Class B (130 degree C) materials.Hi-Pot test of 4,000VAC RMS between primary & secondaryUL recognized to UL506 (XPTQ2.Guide) UL file #E207860CSA certified to C22.2 #66 - CSA file #209651CE compliant to IEC 61558-2-4Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer.Note about Inrush Current: Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longer than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers.Part No.VAVAC Secondary (RMS)Dual or Single Secondary% Voltage RegulationToroid CenterSeriesParallelP-T1182K308060V C.T. @ 1.33A30V @ 2.66ADual9.70%OpenP-T1182L3012060V C.T. @ 2A30V @ 4ADual7.70%OpenP-T1182M3016060V C.T. @ 2.67A30V @ 5.34ADual7.70%OpenP-T1182F3022560V C.T. @ 3.75A30V @ 7.5ADual6.30%OpenP-T1182P3030060V C.T. @ 5A30V @ 10ADual6.10%OpenP-T1182R3050060V C.T. @ 8.33A30V @ 16.66ADual4.80%OpenP-T1182S3062560V C.T. @ 10.42A30V @ 20.84ADual4.10%OpenP-T1182T3075060V C.T. @ 12.5A30V @ 25ADual3.10%OpenP-T1182T30P75060V C.T. @ 12.5A30V @ 25ADual3.10%PottedP-T1182U30100060V C.T. @ 16.7A30V @ 33.3ADual2.20%OpenFor other toroidal secondary voltages, see our other listings:VoltageProduct6V parallel / 12V series secondary9V parallel / 18V series secondary12V parallel / 24V series secondary15V parallel / 30V series secondary18V parallel / 36V series secondary22V parallel / 44V series secondary24V parallel / 48V series secondary30V parallel / 60V series secondaryP-T1182-3040V parallel / 80V series secondary60V parallel / 120V series secondary90V parallel / 180V series secondary110V parallel / 220V series secondary117V parallel / 234V series secondary240V secondary % Voltage Regulation80 versionP-T1182K309.70% 120 versionP-T1182L307.70% 160 versionP-T1182M307.70% 225 versionP-T1182F306.30% 300 versionP-T1182P306.10% 500 versionP-T1182R304.80% 625 versionP-T1182S304.10% 750 versionP-T1182T303.10% 750 potted versionP-T1182T30P3.10% 1000 versionP-T1182U302.20% Height80 versionP-T1182K301.5 in. 120 versionP-T1182L301.63 in. 160 versionP-T1182M301.75 in. 225 versionP-T1182F301.88 in. 300 versionP-T1182P301.88 in. 500 versionP-T1182R302.25 in. 625 versionP-T1182S302.38 in. 750 versionP-T1182T302.88 in. 750 potted versionP-T1182T30P2.88 in. 1000 versionP-T1182U302.88 in. Inside Diameter80 versionP-T1182K301.6 in. 120 versionP-T1182L301.45 in. 160 versionP-T1182M301.70 in. 225 versionP-T1182F301.62 in. 300 versionP-T1182P301.85 in. 500 versionP-T1182R302.30 in. 625 versionP-T1182S302.45 in. 750 versionP-T1182T302.45 in. 750 potted versionP-T1182T30P2.45 in. 1000 versionP-T1182U302.35 in. Lead Length8 in. Outside Diameter80 versionP-T1182K303.5 in. 120 versionP-T1182L304.25 in. 160 versionP-T1182M304.25 in. 225 versionP-T1182F304.5 in. 300 versionP-T1182P304.88 in. 500 versionP-T1182R305.5 in. 625 versionP-T1182S305.88 in. 750 versionP-T1182T305.88 in. 750 potted versionP-T1182T30P5.88 in. 1000 versionP-T1182U306.25 in. Parallel Secondary80 versionP-T1182K3030V @ 2.66A 120 versionP-T1182L3030V @ 4A 160 versionP-T1182M3030V @ 5.34A 225 versionP-T1182F3030V @ 7.5A 300 versionP-T1182P3030V @ 10A 500 versionP-T1182R3030V @ 16.66A 625 versionP-T1182S3030V @ 20.84A 750 versionP-T1182T3030V @ 25A 750 potted versionP-T1182T30P30V @ 25A 1000 versionP-T1182U3030V @ 33.3A Series Secondary80 versionP-T1182K3060V C.T. @ 1.33A 120 versionP-T1182L3060V C.T. @ 2A 160 versionP-T1182M3060V C.T. @ 2.67A 225 versionP-T1182F3060V C.T. @ 3.75A 300 versionP-T1182P3060V C.T. @ 5A 500 versionP-T1182R3060V C.T. @ 8.33A 625 versionP-T1182S3060V C.T. @ 10.42A 750 versionP-T1182T3060V C.T. @ 12.5A 750 potted versionP-T1182T30P60V C.T. @ 12.5A 1000 versionP-T1182U3060V C.T. @ 16.7A Toroid Center80 versionP-T1182K30Open 120 versionP-T1182L30Open 160 versionP-T1182M30Open 225 versionP-T1182F30Open 300 versionP-T1182P30Open 500 versionP-T1182R30Open 625 versionP-T1182S30Open 750 versionP-T1182T30Open 750 potted versionP-T1182T30PPotted 1000 versionP-T1182U30Open Packaging Information Packaging Dimensions80 versionP-T1182K303.5 in. × 3.5 in. × 1.5 in. 120 versionP-T1182L304 in. × 4 in. × 1.63 in. 160 versionP-T1182M304.35 in. × 4.35 in. × 1.75 in. 225 versionP-T1182F304.5 in. × 4.5 in. × 2 in. 300 versionP-T1182P305 in. × 5 in. × 2 in. 500 versionP-T1182R305.5 in. × 5.5 in. × 2.25 in. 625 versionP-T1182S306 in. × 6 in. × 2.5 in. 750 versionP-T1182T306 in. × 6 in. × 2.87 in. 750 potted versionP-T1182T30P6 in. × 6 in. × 2.87 in. 1000 versionP-T1182U306.25 in. × 6.25 in. × 3 in. Weight (Packaging)80 versionP-T1182K303 lbs. 120 versionP-T1182L303 lbs. 160 versionP-T1182M303.6 lbs. 225 versionP-T1182F305.3 lbs. 300 versionP-T1182P305.75 lbs. 500 versionP-T1182R307.75 lbs. 625 versionP-T1182S3010.8 lbs. 750 versionP-T1182T3013 lbs. 750 potted versionP-T1182T30P13 lbs. 1000 versionP-T1182U3016.5 lbs. P-T1182K30 - 80 version% Voltage Regulation9.70% Height1.5 in. Inside Diameter1.6 in. Lead Length8 in. Outside Diameter3.5 in. Parallel Secondary30V @ 2.66A Series Secondary60V C.T. @ 1.33A Toroid CenterOpen P-T1182L30 - 120 version% Voltage Regulation7.70% Height1.63 in. Inside Diameter1.45 in. Lead Length8 in. Outside Diameter4.25 in. Parallel Secondary30V @ 4A Series Secondary60V C.T. @ 2A Toroid CenterOpen P-T1182M30 - 160 version% Voltage Regulation7.70% Height1.75 in. Inside Diameter1.70 in. Lead Length8 in. Outside Diameter4.25 in. Parallel Secondary30V @ 5.34A Series Secondary60V C.T. @ 2.67A Toroid CenterOpen P-T1182F30 - 225 version% Voltage Regulation6.30% Height1.88 in. Inside Diameter1.62 in. Lead Length8 in. Outside Diameter4.5 in. Parallel Secondary30V @ 7.5A Series Secondary60V C.T. @ 3.75A Toroid CenterOpen P-T1182P30 - 300 version% Voltage Regulation6.10% Height1.88 in. Inside Diameter1.85 in. Lead Length8 in. Outside Diameter4.88 in. Parallel Secondary30V @ 10A Series Secondary60V C.T. @ 5A Toroid CenterOpen P-T1182R30 - 500 version% Voltage Regulation4.80% Height2.25 in. Inside Diameter2.30 in. Lead Length8 in. Outside Diameter5.5 in. Parallel Secondary30V @ 16.66A Series Secondary60V C.T. @ 8.33A Toroid CenterOpen P-T1182S30 - 625 version% Voltage Regulation4.10% Height2.38 in. Inside Diameter2.45 in. Lead Length8 in. Outside Diameter5.88 in. Parallel Secondary30V @ 20.84A Series Secondary60V C.T. @ 10.42A Toroid CenterOpen P-T1182T30 - 750 version% Voltage Regulation3.10% Height2.88 in. Inside Diameter2.45 in. Lead Length8 in. Outside Diameter5.88 in. Parallel Secondary30V @ 25A Series Secondary60V C.T. @ 12.5A Toroid CenterOpen P-T1182T30P - 750 potted version% Voltage Regulation3.10% Height2.88 in. Inside Diameter2.45 in. Lead Length8 in. Outside Diameter5.88 in. Parallel Secondary30V @ 25A Series Secondary60V C.T. @ 12.5A Toroid CenterPotted P-T1182U30 - 1000 version% Voltage Regulation2.20% Height2.88 in. Inside Diameter2.35 in. Lead Length8 in. Outside Diameter6.25 in. Parallel Secondary30V @ 33.3A Series Secondary60V C.T. @ 16.7A Toroid CenterOpen 13626182 623980531441 16.5000lbs 0.00 0.00 0.00
Hammond Manufacturing
71.76 2025-07-12 In Stock

Hammond Manufacturing P-T1182-30 Transformer - Hammond Manufacturing, Toroidal Power, 30V / 60V secondary

Shop more from CED

In Stock
*  Click "Add to Cart" to calculate shipping and delivery time.
Share & Earn 10% Cash Back Best Price in Bulk

Product Description

Manufacturer Part Number: P-T1182-30

Dual 117/234 VAC primary, ~frac{50}{60}~ Hz. operation. 60 V series, 30 V parallel secondary.

Toroidal transformers are
  • low profile
  • lightweight
  • cool running / high efficiency
  • have low stray magnetic flux leakage (low EMI) due to core shape

Features:
  • Supplied with two neoprene rubber insulating pads, one metal centering washer and all mounting hardware
  • Minimum 8" long flexible leads
  • Manufactured using Class B (130 degree C) materials.
  • Hi-Pot test of 4,000VAC RMS between primary & secondary
  • UL recognized to UL506 (XPTQ2.Guide) UL file #E207860
  • CSA certified to C22.2 #66 - CSA file #209651
  • CE compliant to IEC 61558-2-4

Note: Units are designed to have all windings engaged (either series or parallel connected) or connected as an autotransformer.

Note about Inrush Current: Due to the superior magnetic properties of Toroidal transformers they will be susceptible to high magnetizing current when initially energized, only limited by the low DC resistance of the primary winding. Depending on where you are in the AC cycle when the transformer is energized dictates the chances of overloading the supply circuit. This is why the transformer may sometimes energize without a problem and other times it will blow the fuse or trip the circuit breaker. The duration of this overload is rarely longer than a half of a cycle. Therefore, you should consider using a slow-blow fuse, time delayed circuit breaker or other form of soft start circuitry for the supply line when using these high efficient Toroidal transformers.

For other toroidal secondary voltages, see our other listings:






warning tips WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov.